Part Number Hot Search : 
050000 MAX14 KTD1028 R6011 LTC69 MBZ27 FDMS86 MN100
Product Description
Full Text Search
 

To Download A74-11 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  specifications are subject to change without notice (19.07.06) 1 current and voltage controls ? 3-phase current metering transformers f or use with current control relays ? measuring ranges: a 74-10 5: 0.5 - 5 aac a 74-10 20: 2 - 20 aac a 74-11 100: 10 - 100 aac a 74-11 500: 50 - 500 aac product description 3-phase current transformer measures on all three phases. output voltage pr oportional ordering key type input current to measured amplitude of the rms-value of the normal phase cur rent. type selection input cur r ent type no. 5 aac a 74-10 5 20 aac a 74-10 20 100 aac a 74-11 100 500 aac a 74-11 500 input specifications a 74-10 5 a 74-10 20 a 74-11 100 a 74-11 500 output voltage (t a = 20 = 68?, r l = 9.5 k ) 0.4 - 4 v p 0.4 - 4 v p 0.4 - 4 v p 0.4 - 4 v p output impedance < 700 < 200 < 40 < 10 t olerance of output voltage @ rated input current 5% 5% 5% 5% t emperatur e variation 0.1% per c 0.1% per c 0.1% per 0.1% per rated insulation voltage (cable) 250 v ac r ms 250 v ac r ms 250 v ac r ms 250 v ac r ms output specifications current transformer, 3-phase types a 74-10, a 74-11 a 74-10 5 a 74-10 20 a 74-11 100 a 74-11 500 cur rent range 0.5 - 5 aac 2 - 20 aac 10 - 100 aac 50 - 500 aac max. current (continuously) 20 aac 50 aac 250 aac 750 aac max. overload current (t = 30 s) 40 aac 85 aac 325 aac 1000 aac rated insulation voltage input-output 1000 v ac r ms 1000 v ac r ms 1000 v ac r ms 1000 v ac r ms overvoltage category iv (iec 60664) iv (iec 60664) iv (iec 60664) iv (iec 60664) dielectric strength dielectric voltage 6 kvac rms 6 kvac rms 6 kvac rms 6 kvac rms rated impulse withstand volt. 12 kv (1.2/50 s) 12 kv (1.2/50 ?) 12 kv (1.2/50 ?) 12 kv (1.2/50 ?) power consumption < 0.1 w@5 a < 0.25 w@20 a < 1.5 w@100 a < 21 w@1500 a a 74-10 5
2 specifications are subject to change without notice (19.07.06) a 74-10, a 74-11 general specifications p ollution degree 3 (iec 60664) a mbient temperature - 20 to + 60 (--4 to + 140) h ousing d imensions a74-10 120 x 45 x 16 mm a 74-11 150 x 114 x 23 material abs weight a 74-10 200 g a 74-11 750 g connection cable 2 m pvc, 4 x 0.4 mm 2 a pproval u l ce marking ye s t he current metering trans- f ormer is connected to the current control relays h 475 as follows: red core to term. 5 - u 1 . white core to term. 6 - u 2 . yellow core to term. 7 - u 3 . black core to term. 8 . ( starpoint - neutral). the metered conductor is drawn through the central hole of the current metering transformer. drawing the con- mode of operation d uctor through the hole sever- a l times makes it possible to meter currents below the no- minal range. if the conductor is drawn through the central hole e.g. 5 times, the metering trans- former will register 50 a when t he current in the conductor is 1 0 a. in amplitude and phase the output voltage is proportional to the phase current metered. wiring diagrams output voltage a 74-10 .. a 74-11 .. input current red white yellow black u 1 red black u 3 y e llow u 2 white u 1 red u 2 white u 3 y ellow black dimensions correct connection i ncor rect connection


▲Up To Search▲   

 
Price & Availability of A74-11

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X